Close
Medical

Medtronic NIM-ECLIPSE IONM 945ECLC Set

$8000 by Bookoo Fan in A secret location, 3 days ago
Send Message
Medtronic NIM-ECLIPSE IONM 945ECLC Set in Los Angeles
Medtronic NIM-ECLIPSE IONM 945ECLC Set in Los Angeles
Medtronic NIM-ECLIPSE IONM 945ECLC Set in Los Angeles
Medtronic NIM-ECLIPSE IONM 945ECLC Set in Los Angeles
Medtronic NIM-ECLIPSE IONM 945ECLC Set in Los Angeles
Medtronic NIM-ECLIPSE IONM 945ECLC Set in Los Angeles

For sale is a like new condition Medtronic NIM-ECLIPSE IONM 945ECLC Set.

What is Included
1. Medtronic NIM-ECLIPSE IONM 945ECLC CONTROLLER
2. Medtronic NIM-ECLIPSE IONM Patient Interface Module OPM660 / 945OPM660
3. Power Cord
4. 90 Day Warranty



The Patient Interface Module (PIM), PN OPM660 / 945OPM660, provides the means for connecting the patient to the NIM-ECLIPSE® System. The PIM contains the recording electrode amplifier and electrical stimulator to connect to probes, MEP and TOF electrodes. The Patient Interface Module has inputs for one or two (left and right) pulse oximeters. The PIM accepts recording electrodes from subdermal needle, traditional and No Prep surface electrodes. When No-Prep triple contact surface electrodes are used, the Active Electrodes Preamplifier, PN SPM608 / 945SPM608, must be connected to the Active Electrodes Input connector. Note: When the SPM608 / 945SPM608 Active Electrodes Preamplifier is connected, do not plug additional recording electrodes into the OPM660 / 945OPM660 Patient Interface Module. The PIM connects to the NIM-ECLIPSE® System Controller via a two connector, 20ft cable.

7.5.1 PIM RECORDING ELECTRODE INPUTS Eight numbered and color-coded recording channels are provided grouped in two sets (left and right) of four channels. Electrode inputs of channels one through four are marked with a black outline to indicate left side electrode placement. Channels five through eight are marked with white outline to indicate right side electrode placement. (Mnemonic: white is right). Color-coded electrode leads connect to their respective color-coded channels. Two electrodes per channel are required. Certain tests may require fewer than eight channels.

The Active Electrodes Preamplifier (AEP), PN SPM608 / 945SPM608, allows the use of proprietary, “No Prep” triple contact surface electrodes. The electrodes can be applied to the patient without special skin preparation and yet provide high quality recording. The AEP interfaces to the PIM via a 4 ft cable and connects to the Active Electrodes Input connector. When properly connected, the AEP power on indicator will be illuminated. Eight pods are color-coded and marked with channel numbers. Snap all three contacts of the triple electrode into each of the eight AEP pod receptacles. Remove the plastic backing to expose the electrodes and then apply to the patient. Apply the electrodes such that the two top electrodes are parallel to the muscle belly. If the test protocol uses fewer than eight channels, unused pods may be left open and unconnected.

7.5.2.1 LARYNGEAL ELECTRODE ADAPTER The Laryngeal Electrode Adapter PN LEA300 / 945LEA300 is used with the Active Electrodes Preamplifier to allow connection to laryngeal electrode leads when laryngeal monitoring is used in the procedure. One or two channels of laryngeal monitoring can be accommodated. The LEA300 / 945LEA300 Adapter has a color-coded label to allow left and right channel to be differentiated. Following the monitoring test protocol, snap the LEA300 / 945LEA300 Adapter into the appropriate channel(s) of the Active Electrode Preamplifier pods. Connect the leads of the color-coded Adapter to the corresponding leads of the laryngeal electrodes.

The NIM-ECLIPSE® System provides stimulation suitable for peripheral, direct nerve and transcranial electrical motor evoked potentials (TCeMEP). The stimulators are electrically isolated from the patient and the outputs are protected by both hardware and software fault detectors to insure patient safety. Patient current is displayed for both constant current and constant voltage stimulation modes. The PIM stimulation panel contains the connections for probes, and for transcranial motor evoked potentials (TCeMEP) and train of four (TOF) electrodes.

7.5.3.1 PROBE OUTPUTS These outputs connect to the surgeon-controlled probe and electrified instruments. In both cases, a return electrode must be connected from the Stim Return connector to the patient. The Stim Control and Instrument output polarity is negative (-) and the Stim Return reference polarity is positive (+). The single use surgeon controlled probe with detachable tips allows remote adjustment of the stimulation current and control of the test through the user interface. The probe has two buttons for control, a multicolor LED indicator that provides test and status information and a buzzer for button press audio feedback. The surgeon-controlled probe is presterilized and designed for single use only. A warning message will appear on the display screen if the probe is used twice after an 18-hour period.

7.5.3.2 MEP OUTPUT The MEP output is used to deliver high current, biphasic, transcranial electrical stimulation to elicit motor evoked potentials at selected muscle sites. MEP parameters are defined in Settings > MEP. The MEP output connectors are specially keyed to accept only the MEP electrode. Open the online Setup Help feature to aid in the pl

Posted in: Medical.
Send Message
Posted By: Bookoo Fan More From:

Join the 2,015,027 happy neighbors and get started selling and saving!

There's even a "You Must Be Happy" Guarantee.

Local
Buy & Sell
94,000+
Followers
2,015,027
Neighbors
Family
Friendly

©2024 Bookoo, Inc. 2270 US Highway 30, Oswego, IL 60543. Dedicated to our families.